|  | Why do I need a monitored security system? Homes without security systems are about 3 times more likely to be broken into than homes with secur..
    Last modified:2007-12-16 Number of views:577 |  | Can installing a security alarm save me money on my home owners insurance? "While a security system may benefit you financially through insurance disc.. Not rated yet Last modified:2007-12-16 Number of views:598 |  | What is the differance between a local alarm and a monitored alarm?
A local alarm means you will have an outside siren and will be depending upon your.. Not rated yet Last modified:2007-12-24 Number of views:507 |  | Are the magnetic sensors for doors and windows wired ? If yes how does the wiring work in parallel or serial for a zone? I have a alram system in my house with windows of this type . We are making a small extesnion with 5 more windows , I was wondering if I can extend the exisitng alram on the last window to the new windows by buying wires and sensors from you. Window and door sensors are always wired in series. You can extend from your last window to include ..
    Last modified:2008-2-24 Number of views:537 |  | In the interest of child safety, can a system be set to chime when we are home and the doors are left open or ajar?Thanks Yes, all professional systems will chime when a door or window is opened. Wired and wireless systems.. Not rated yet Last modified:2008-3-09 Number of views:400 |  | Can a monentary arming key be used along with the 6148 key pad with the Ademco 4110XM kit or do I need a second 6148 key pad? Also does the 4110 support a warning alarm when you enter a house with the alarm on? I am ready to order when I get your answers. Thanks. Alarms today are more like computers then the relay boxes of old. The keypad is a data-in - data-out.. Not rated yet Last modified:2008-5-28 Number of views:431 |  | what the best glue to attach the sensors Most sensors use a durable double stick tape. You can scrape off the soft tape, and clean both the b.. Not rated yet Last modified:2008-8-30 Number of views:327 |  | Just bought the 4110xm-advpk, with the 6148 controller--hooked it all up and can't get the keypad to function. It lights up and reads-- check 05. won't let me bypass that zone, and it won't let me put in my own security code. My 4110xm doesn't list the 6148 as being compatible---is it?? The 6148 is newer than the manual printing, but it is the correct keypad to use for the 4110 Series...
    Last modified:2008-9-15 Number of views:368 |  | Would heat blowing out of the furnace set off a IS2535 Passive Infrared Motion Sensor w/selectable pet immunity?
We installed two diffrent alarm systems in two diffrent buildings and one of our buildings have went off a number of times, the police have been called about it and we would not like another scene, so I reponse as quick as possible would be great. Yes it is possible, motions are looking for a temperature difference that would represent a body mov.. Not rated yet Last modified:2008-11-26 Number of views:239 |  | I am interested in the Honeywell 4110 Kit. What happens if your phone line is severed? I know the battery backup will sound alarms but is that all?
Thanks,
Joe Cellular backup can be provided by your monitoring complany, but there is a fee for the equipment an.. Not rated yet Last modified:2009-2-07 Number of views:186 |  | HI FRANK,
I WATCHED YOUR VIDEOS AND WAS WONDERING IF YOU WIRE A DAILER AS DESCRIBED IS IT PROTECTED BY LINE SEIZURE? THANKS no, the voice dialer does not do line seizure Not rated yet Last modified:2009-2-11 Number of views:165 |  | can the plungers that you provide replace the magnetic sensors Yes if they are on the hinge side of the door.... Not rated yet Last modified:2009-5-14 Number of views:142 |  | For the standard motion detectors or PIR bundled in the Vista20SP kit, What is generally the range and angle or width of detection?
I have seen there are lenses that increase the range but I assume that this would reduce the angle or width.
Also this may sound silly but would a fish tank with lights on a timer trigger the alarm? The aurora motion has two lens, a 35 x 40 foot and a 75 x 10 foot coverage area at the recommended 7.. Not rated yet Last modified:2009-8-16 Number of views:94 |  | I mistakenly unpluged my AC power plug for a day. Now I am not able to get my system to arm when I enter my code>? Its stated that the system is ready, but does not seem to acknowledge my code entry. It does arm if I push # plus the instant key but even then I can not get it to turn off. Sounds like it may have reset the code? This should not happen, but I would run through the program .. Not rated yet Last modified:2009-9-29 Number of views:92 |  | Im considering purchasing the Power Max plus wireless security system. My question is, can i add a wireless outdoor siren to this system? And does your company offer any of these? Yes David, you can find it here: http://www.udoitalarms.com/fullywirelessalarmsirenstrobforpowermaxp.. Not rated yet Last modified:2010-2-13 Number of views:10 |
|
 |
 |
|  | I just had an upstairs window relaced and now the alarm sensor is hanging in the room by its wire. If I cut the sesor off how do I eliminate that sesor from being monitored? Ron, you can just twist the wires together to make the alarm think the window is closed. A more secu.. Not rated yet Last modified:2010-2-22 Number of views:9 |  | Im considering purchasing the Power Max plus wireless security system. My question is, can i add a wireless outdoor siren to this system? And does your company offer any of these? Yes David, you can find it here: http://www.udoitalarms.com/fullywirelessalarmsirenstrobforpowermaxp.. Not rated yet Last modified:2010-2-13 Number of views:10 |  | I have a 4 wire safehouse (Radio shack) burglar/fire alarm system. . .20 years old (smoke detector model 49-481) appears it hasn't worked for awhile (some one installed battery units), system is on but won't arm, detectors will not alarm. I'm wanting to use existing wiring and replace the system. Wired: windows, 6 doors, 6 smoke detectors, panic button, indoor two-tone siren. I would like best wat to go to work to save $$$.
thanks for your time The Honeywell/Ademco system on sale here: http://www.udoitalarms.com/ademco4110xmfullfunctionsecurit.. Not rated yet Last modified:2010-1-30 Number of views:11 |  | I purchased a 10yrold house with a wired alarm, windows are wired w/sensors,and motion sensors the system is not working, can i buy your alarm and use it to run my system?the video did not discuss this.thanks Yes. Alarm sensors are standard for almost all systems these days. A new alarm package with a contro.. Not rated yet Last modified:2010-1-26 Number of views:7 |  | we have disconected our alarm from "Brinks" and wish to make it a "local alarm only" how does one do that? If you have the codes you can reprogram it to not call. If that is not possible, sometimes just unpl.. Not rated yet Last modified:2010-1-21 Number of views:12 |  | I watched your video and understand how the autodialer works. Do you know of a system that can connect to my home computer and send me a email message. I have a Blackberry and I am more likely to get an email message in a timely manner than I would get a phone message. Hi Roy, there are two systems that you can use. This one: http://www.udoitalarms.com/internetreadyvi.. Not rated yet Last modified:2010-1-07 Number of views:26 |  | I have an older ademco 4110 it takes multiple tries to get alarm set it goes off after leaving, sometimes it will work after 1 try sometimes after several tries other times and it doesn't give a zone code after it goes off. Any Ideas? Over time some keypads will loose their senitivity. Sometimes changing your code to "new" numbers wi.. Not rated yet Last modified:2009-11-16 Number of views:55 |  | I am looking to replace my 30yo hardwired home alarm system. It is acting funny (or not at all lately) and want to replace the hardware and use the wiring. My system is as follows:
1 - alarm box
1 - keyed alarm activator/indicator (red/green light) for inside the house
1 - keypad activator/indicator for the entrance of the house
1 - audible alarm bell (school bell type)
Several doors, windows, etc. are monitored
What do you suggest I can purchase to replace this system with little or no rewiring.
Thank you
Anthony De Lisa Intella-Home's Honeywell basic package sounds like it will work for you. You can check it out here: .. Not rated yet Last modified:2009-10-29 Number of views:71 |  | how can i fix magnet that came unglued from window Clean the magnet and window with alcohol, then use new double-stick, peel and press on. Not rated yet Last modified:2009-10-25 Number of views:56 |  | i am looking at installing a wired security system in a frends garage business that has 7 entry doors and will require 6 motion detectors for coverage, i understand i can link multiple doors to a zone (i.e. s front showroom entry doors not needing entry delay can be linked together as a zone by themselves correct?)
can i or how would i do the same for motion detectors?
also, how many sirens can the advertised complete system( for 199.00) support ? the 2 it comes with and i was also going to ass 1 more external for loudness will this unit support 3 sirens? and with 6 zones will it support all these entry doors as well as all these motions if the do not need to be identified per zone( i.e. 13 seperate zones)please respond to me at jimsmobile1@hotmail.com, or email me a link identifying i have a reply here
thanks you jim Hi Jim, motions can be connected in series just like doors. The only thing that may be a problem is .. Not rated yet Last modified:2009-10-12 Number of views:73 |  | I have had a Honeywell Ademco wired/wireless system installed for a couple years now from Guardian. I have three wired Honeywell IS215T PIM Motion Sensors installed/mounted throughout the home as part of the system. My question is I am sure one of them is broken, I checked all the circuits in the main panel and there is power to the motion. Since it’s wired can I just swap the old motion with an exact replacement? Or will I have to program anything? Wayne, a direct replacement will work fine. You would only have to program if it was wireless. Not rated yet Last modified:2009-10-06 Number of views:90 |  | I mistakenly unpluged my AC power plug for a day. Now I am not able to get my system to arm when I enter my code>? Its stated that the system is ready, but does not seem to acknowledge my code entry. It does arm if I push # plus the instant key but even then I can not get it to turn off. Sounds like it may have reset the code? This should not happen, but I would run through the program .. Not rated yet Last modified:2009-9-29 Number of views:92 |  | I am planning to buy and install a system from you for my condo. It was prewired at all doors and windows.The windows have the magnetic sensors and all wires run to the closet . This is great, but they are not identified. How can I identify them . At the wired window end , there are no areas to check for continuity, other than piercing the conductors. Also , the installed sensors do not have the the other halves. Are they generic?
The sensors are marked Y0204TR15 Hi Dave, We use a meter with a buzzer built in and connect it to the wires in the closet then open a.. Not rated yet Last modified:2009-9-13 Number of views:54 |  | I have setup my ICM module and when I arm the system I do get the e-mail alert so I know it is configured properly. However, when I go to the home screen and try to arm the system from my browser, nothing happens. Any idea's. I am currtnly on address 17 for this pannel. I have a touch screen and a standard key pad on the system as well.
Also, how can I get into the ICM from outside my home, like when at the office and want to arm or disarm the system remotely. Thanks for your help. If it is configured correctly it may be java problem on your computer. Check you security settings a.. Not rated yet Last modified:2009-9-03 Number of views:100 |  | i had an alarm system installed when my home was built. Never had it activated and was wondering how to turn it on so when a door or window is opened the system beeps. I don't care about the alarm just would like to be notified when something is opened. My old alarm would do this.
the control is a honeywell panel and I cannot figure out how to even turn it on.
any help would be greatly appreciated.
thanks you will need to have a code for the system, once you do, enter the code and then press the chime ke.. Not rated yet Last modified:2009-9-02 Number of views:106 |
|
 |
|
 |
| |
    Not rated yet         Not rated yetNot rated yetNot rated yetNot rated yet              Not rated yetNot rated yet    Not rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yet              Not rated yetNot rated yet    Not rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yet
 |
I am in the process of installing and testing a 4110xm. Two questions.
1. Do the End of line resistors (EOLR) need to be installed if all switches are Normally Closed? The schematic shows an EOLR connect to one side of an open switch and the other side going directly to the low side of the panel. I guess my question is, is the EOLR always required regardless of what type of switch is installed? (NC, NO) If the last switch in the loop in NC does the EOLR go from the low side of the switch to the directly to the panel screw?
2. I am installing several switches on 4 zones. All hardwired (no wireless, RF at all) For trouble shooting purposes and for clarity in describing my problem, I disconnect and disabled (programmed) all zones except zone one. (zones, 2, 3, 4, 5, and 6 are currently disabled) On zone one I have a NC magnet switch with an EOLR connected. Regardless of what I do, the key pad continues to give a trouble tone and displays "check 9". Meaning I have a fault on zone 9. My panel only has six hard wired zones. However, on the programming form "Zone 9" is for "alarm report code, RF supervision" But I have no RF devices! I have followed the programming steps for Data field 59 (zone 9) that claims it disables the report by entering a "0" in the first digit. (I key in # plus 10 to send a zero according to the instructions) After exiting the programming mode I get a green ready light but a miniute later the Check 9 returns with the trouble tone. What the heck is going on and how do I fix it?
Feel free to call me if you need to and Thanks a ton……..
Scott
260-750-8079
|
Not rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yetNot rated yet |
|
 |
|
|